  data sheet 1 2000-07-01 the ksy 14 is an ion-implanted hall sensor generator in a mono-crystalline gaas material, built into an extremely flat plastic package (soh). it is outstanding for a high magnetic sensitivity and low temperature coefficients. the 0.35 0.35 mm 2 chip is mounted onto a non-magnetic leadframe. type marking ordering code ksy 14 14 q62705-k227 hall sensor ksy 14 version 2.0 dimensions in mm features ? high sensitivity ? high operating temperature ? small linearity error ? low offset voltage ? low tc of sensitivity and internal resistance ? ultra-flat plastic miniature package ? low inductive zero component ? package thickness 0.7 mm ? connections from one side of the package typical applications ? current and power measurement ? magnetic field measurement ? control of brushless dc motors ? rotation and position sensing ? measurement of diaphragm ? movement for pressure sensing
data sheet 2 2000-07-01 ksy 14 absolute maximum ratings electrical characteristics ( t a = 25 c) parameter symbol limit values unit operating temperature t a C 40 ? + 175 c storage temperature t stg C 50 ? + 180 c supply current i 1 7ma thermal conductivity soldered, in air g tha g thc 3 1.5 3 2.2 mw/k mw/k nominal supply current i 1n 5ma open-circuit sensitivity k b0 190 ? 260 v/at open-circuit hall voltage i 1 = i 1n , b = 0.1 t v 20 95 ? 130 mv ohmic offset voltage i 1 = i 1n , b = 0 t v r0 20 mv linearity of hall voltage b = 0 ? 0.5 t b = 0 ? 1 t f l 0.2 0.7 % % input resistance b = 0 t r 10 900 ? 1200 w output resistance b = 0 t r 20 900 ? 1200 w temperature coefficient of the open-circuit hall voltage i 1 = i 1n , b = 0.1 t tc v20 ~ C 0.03 ? C 0.07 %/k temperature coefficient of the internal resistance b = 0 t tc r10, r20 ~ 0.1 ? 0.18 %/k change of offset voltage within the temperature range ?d v r0 ? 1) 2mv inductive zero component i 1n =0 a 2 2) 0.16 cm 2 noise figure f ~ 10 db 1) aql: 0.65 2) with time varying induction there exists an inductive voltage v ind between the hall voltage terminals (supply current i 1 = 0): v ind = a 2 d b /d t 10 -4 with v (v), a 2 (cm 2 ), b (t), t (s)
data sheet 3 2000-07-01 ksy 14 connection of a hall sensor with a power source since the voltage on the component must not exceed 10 v, the connection to the constant current supply should only be done via a short circuit by-pass. the by-pass circuit-breaker shall not be opened before turning on the power source, in order to avoid damage to the hall sensor due to power peaks. polarity of hall voltage


▲Up To Search▲   

 
Price & Availability of KSY14

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X